Innovative specialist for challenging applications, as remote version with up to 4 I/Os
-
Measuring principle
Coriolis
-
Product headline
State-of-the-art specialist designed for challenging applications, offered as a remote version supporting up to 4 I/Os.
Ensured measurement accuracy – unmatched precision in mass flow, volume flow, and density.
Unrivaled measurement performance for custody transfer, density, and demanding process conditions. -
Sensor features
Improved performance for liquids with entrained gas bubbles – MFT (Multi-Frequency Technology). Decreased number of process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no requirement for in-/outlet runs.
Mass flow: measurement error ±0.05% (PremiumCal). Density: measurement error ±0.2 kg/m?. High turndown ratio achieved through low pressure loss/zero point. -
Transmitter features
Comprehensive availability of process and diagnostic information – ample, freely combinable I/Os and fieldbuses. Streamlined complexity and flexibility – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version offered with up to 4 I/Os. Backlit display featuring touch control and WLAN access. Standard cable connection linking the sensor and transmitter. -
Nominal diameter range
DN 25 to 250(1 to 10″)
-
Wetted materials
Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): +/-0.2 kg/m? (standard), +/-0.1 kg/m? (option) -
Measuring range
0 to 2 400 000 kg/h (0 to 88183 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +205°C (–58 to +401 °F)
Option: –196 to +150 °C (–321 to +302 °F) -
Ambient temperature range
Standard: – 4 to +60 °C (–4 to +140 °F)
Option:–60 to +60 °C (–76 to +140 °F) -
Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L -
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
-
Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (T?V S?D attestation)
MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic liquids)
OIML R117 (Liquids other than water, Liquified gases, Cryogenic liquids)
NTEP (Liquids other than water, Cryogenic liquids)
MC (Liquids other than water, Cryogenic liquids) -
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK -
Hygienic approvals and certificates
3-A, EHEDG, cGMP