Versatile standard flowmeter for the water and wastewater industry
-
Measuring principle
Electromagnetic
-
Product headline
Versatile Standard Flowmeter for Water and Wastewater Industry
Reliable Measurement at Constant Accuracy with 0 x DN Inlet Run and No Pressure Loss
Ideal for Water Measurement Applications (Drinking Water, Utility Water, Industrial/Municipal Wastewater) -
Sensor features
Flexible Engineering with Fixed or Lap-Joint Process Connections
Application Fitness with EN ISO 12944 Corrosion Protection for Underground or Underwater Installation
Improved Plant Availability with Sensor Compliant to Industry-Specific Requirements
International Drinking Water Approvals
Degree of Protection IP68 (Type 6P Enclosure)
Approved for Custody Transfer to MI-001/OIML R49 -
Transmitter features
Safe Operation with Display, Touch Control, and Background Lighting
Time-Saving Local Operation via Integrated Web Server
Integrated Verification with Heartbeat Technology
Transmitter Housing: Polycarbonate or Aluminum
WLAN Access
Integrated Data Logger for Measured Values Monitoring -
Nominal diameter range
DN 25 to 3000(1 to 120″)
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec -
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) -
Ambient temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) -
Sensor housing material
DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 25 to 2000 (1 to 78″): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate -
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish
according to EN ISO 12944 C5‐M/Im1/Im2/Im3
Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools possible -
Outputs
3 ouputs:
0‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency output (passive)
Switch output (passive) -
Inputs
Status input
-
Digital communication
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485
-
Power supply
AC 100…240 V / AC/DC 24 V
-
Hazardous area approvals
cCSAus
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run) -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920