Refueling application flowmeter with easy system integration
-
Measuring principle
Coriolis
-
Product headline
This flowmeter can be easily integrated into refueling systems and provides accurate measurement of CNG usage. It is suitable for high pressure CNG refueling applications, offering precise measurement data.
-
Sensor features
Excellent operational safety is provided by this flowmeter, as it remains reliable even under extreme process conditions. By offering multivariable measurement of flow, density, and temperature, the number of required process measuring points is reduced. The compact, space-saving installation requires no inlet or outlet run. This flowmeter can handle flow rates up to 150 kg/min (330 lb/min) and process pressures up to 350 bar (5080 psi), making it well-suited for high pressure compressed natural gas (CNG) refueling applications.
-
Transmitter features
Easy operation is achieved by reducing the device to only the necessary application requirements. Fast commissioning is enabled through pre-configured devices. Automatic recovery of data facilitates servicing and maintenance. The transmitter housing is robust and ultra-compact in design. This flowmeter provides a pulse output as well as Modbus RS485 communication, allowing for easy integration into a variety of refueling systems.
-
Nominal diameter range
DN 8 to 25 (? to 1″)
-
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316) -
Measured variables
Mass flow, density, temperature, volume flow
-
Max. measurement error
Mass flow: ±0.5 % of batch
-
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
-
Max. process pressure
350 bar (5080 psi)
-
Medium temperature range
–50 to +125 °C (–58 to +257 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
-
Degree of protection
IP67, type 4X enclosure
-
Display/Operation
No local operation
Configuration via operating tools possible -
Outputs
Pulse/frequency/switch output (passive), phase‐shifted pulse
-
Inputs
None
-
Digital communication
Modbus RS485
-
Power supply
DC 10 to 30 V AC 20 to 28 V
-
Hazardous area approvals
ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
PTB, BEW, LNE, Rosstandart, NTEP approvals -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material