For accurate measurement in both gases and liquids, a digital pressure transmitter with an oil-free ceramic sensor is recommended. This type of transmitter provides reliable and precise readings without the risk of oil contamination, making it suitable for a wide range of applications.






Specs at a glance
-
Accuracy
Standard: 0.05%
Platinum: up to 0.025% -
Process temperature
-40°C…150°C
(-40°F…302°F) -
Pressure measuring range
100mbar…40bar
(1.5psi…600psi) -
Process pressure / max. overpressure limit
60bar (900psi)
-
Main wetted parts
Ceraphire ceramic
Alloy C
316L
Monel
PVDF -
Max. measurement distance
400m (1312ft) H2O
-
Material process membrane
Ceramic
-
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
relative/ absolute
Field of application
The Cerabar PMC71 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in the process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2/3 according to IEC 61508.
Two chamber aluminum or stainless steel (316L) housing.
-
Process connections: Threads, flanges or hygienic connections
-
Process temperature: -40 to +150°C (-40 to +302°F)
-
Measuring ranges: -1/0 up to to +40bar (+1.5 to +600psi)
-
Accuracy: ±0.05%, “Platinum” ±0.025%
-
International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
Benefits
-
Best fit for vacuum applications and applications with corrosive and abrasive media
-
Process safety through membrane breakage detection
-
Overload-resistant high purity ceramic sensor (99.9% Al2O3)
-
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
-
Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
-
Available with mounted manifolds: always fit, always tested for leaks
Specifications
-
Characteristic
Digital transmitter with capacitive sensor and ceramic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Supply voltage
4…20 mA HART
10,5…45V DC (Non Ex):
Ex ia: 10,5…30V DC
PROFIBUS PA:
9…32 V DC (Non Ex)
FOUNDATION Fieldbus:
9…32 V DC (Non Ex) -
Reference Accuracy
Standard: 0.05%
Platinum: up to 0.025% -
Long term stability
0.05 % of URL/ year
0.08 % of URL/ 5 years
0.1 % of URL/ 10 years -
Process temperature
-20°C…150°C
(-4°F…257°F) -
Ambient temperature
-40°C…85°C
(-40°F…185°F) -
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
relative/ absolute -
Smallest calibratable span
5 mbar (0.075 psi)
-
Vacuum resistance
0 mbar abs.
-
Max. Turn down
100:1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Thread:
G1/2…G2, R1/2, MNPT1/2…MNPT2
Flange:
DN25…DN80,
ASME 1″…4″,
JIS 10K -
Process connection hygienic
Tri-Clamp
DIN11851
Varivent N
SMS
DRD -
Material process membrane
Ceramic
-
Material gasket
Viton, EPDM, Chemraz, Kalrez, NBR
-
Fill fluid
none, dry measuring cell
-
Material housing
Die-cast aluminum,
AISI 316L -
Communication
4…20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex
-
Design approvals
EN10204-3.1
-
Hygienic approvals
3A, EHEDG
-
Marine approvals
GL/ ABS
-
Drinking water approvals
NSF
-
Specialities
Diagnostic functions
-
Successor
PMC71B
-
商品評價