OPTIBAR P 2010
Pressure transmitter for hygienic pressure and level applications
- Ultra-compact design with flush diaphragm: with 3A certification
- 0.1…40?bar?/ 4…580?psi; max. +150°C?/ +302°F (for SIP/CIP)
- Many hygienic connections available
- 2-wire 4…20?mA
Specifications
Depending on selected device configuration
General information
Product type Pressure transmitter Product family name OPTIBAR Product positioning For hygienic pressure and level applications Measurement principle Hydrostatic Measured media Liquids, Gases Measuring point Open tank Operating conditions
Process pressure max. 40 bar/
580 psiProcess temperature -40…+150°C/
-40…+302°FMaterials
Diaphragm Austenitic stainless steel (1.4435/316L) Fill fluid Silicone oil, Food grade oils (FDA listed) Measuring cell seal Fluoroelastomer rubber (FKM), Perfluoroelastomer rubber (FFKM) Process connections
Thread connections Male:
Hygienic G?, G1 for hygienic adapters
G?, G?, G1 (DIN 3852)Hygienic adapters Clamp (DIN 32676): DN25, DN32, DN40, DN50
Clamp (ISO 2852): 25, 38 51
Tri-Clamp: ?”, ?”, 1″, 2″
Collar ferrule (DIN 11851): DN25, DN40, DN50
VARIVENT??NApprovals/Standards
Certificates/Approvals Ex ATEX, IECEx Certificates/Approvals Hygienic FDA, 3A, EC 1935/2004 Certificates/Approvals Others Pressure Equipment Directive (PED) Communication
Analogue outputs 0…10?VDC, 4…20?mA Overview
The OPTIBAR P 2010 is an ultra-compact pressure transmitter with flush diaphragm for hygienic pressure and level applications in the food and beverage as well as in the pharmaceutical industry. It is perfectly suited for front-flush and aseptic installation. The versatile pressure and level transmitter provides a repeatable measuring signal that is stable over the long term, even with regular SIP/CIP cleaning cycles, while simultaneously guaranteeing a high degree of chemical resistance to process and cleaning solutions.
Features & Options
The modular design of the OPTIBAR?P?2010 allows combining a wide range of fully welded process connections with a variety of filling media and electrical connections so as to accommodate virtually any hygienic requirement. Optional cooling fins can be added to handle continuous process temperatures up to +300°C?/ +572°F.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Fully welded hygienic design with surface roughness of Ra <0.4?μm
- Suitable for SIP (Sterilisation In Place) and CIP (Cleaning In Place)
- 3A certified process connections
- Extraordinary accuracy of ±0.25%
- Outstanding temperature stability
- Long-term stability: ±0.1%/year (uncertainty)
- Modular design: free combination of device options such as electrical connections, diaphragm material, fill oil, measuring range, process connections
- Ingress protection up to IP68 / NEMA 6P
- ATEX/IECEx intrinsically safe approval for Zone 0
商品評價