Electronic differential pressure system utilizing two ceramic sensor modules and one transmitter



Specs at a glance
-
Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor
-
Process temperature
–25…+150°C
(–13…+302°F)
-
Pressure measuring range
100mbar…40bar
(1.5psi…600psi)
-
Process pressure / max. overpressure limit
60 bar (900 psi)
-
Material process membrane
Ceramic
316L, AlloyC
-
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi)
Field of application
The Deltabar FMD71 is an electronic differential pressure system used to measure pressure, level, volume, or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure, while the low pressure sensor (LP) measures the head pressure. The level is then calculated in the transmitter using these two digital values. This electronic differential pressure system eliminates the issues associated with traditional differential pressure measurements.
For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.
-
Process connections: Threads, flanges and hygienic connections
-
Process temperature: -40 up to +150°C (-40 to +302°F)
-
Measuring range: 100mbar to +40bar (6 to 600psi)
-
Accuracy: Single sensor up to ±0.05%, system up to ±0.07%
-
International explosion protection certificates, hygienic approvals
Benefits
-
Eliminates traditional mechanical issues resulting in greater process availability and reliability
-
Overload-resistant high purity ceramic sensor (99.9% Al2O3)
-
Safety risks are minimized with the new electronic differential pressure system architecture and design
-
Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements
-
Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system
-
Continuous health indication of the entire system via HART-based diagnostic
-
High reproducibility and long-term stability
Specifications
-
Characteristic
Electronic differential pressure transmitter with ceramic sensor (Ceraphire) for level, volume or mass measurement in liquids.
-
Supply voltage
4…20 mA HART:
12…45V DC (Non Ex)
Ex ia: 12…30V DC -
Reference Accuracy
0.075% of individual sensor,
“PLATINUM” 0.05% of individual sensor -
Long term stability
0.05% of URL/year of individual sensor
-
Process temperature
–25…+150°C
(–13…+302°F) -
Ambient temperature
–40…+80°C
(–40…+176°F) -
Measuring cell
100 mbar…40 bar
(1.5 psi…600 psi) -
Vacuum resistance
0 mbar
-
Max. Turn down
100 : 1
-
Max. overpressure limit
60 bar (900 psi)
-
Process connection
Threads
Flansch (DIN, ASME, JIS) -
Process connection hygienic
DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent -
Material process membrane
Ceramic
316L, AlloyC -
Material gasket
Viton, Kalrez, EPDM, NBR, Silicone
-
Fill fluid
Silicone Oil
-
Material housing
Die-cast aluminum
Stainless steel -
Communication
4…20 mA HART
-
Certificates / Approvals
ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
-
Design approvals
NACE MR0175,
EN10204-3.1, -
Hygienic approvals
EHEDG,
3A
商品評價