Flowmeter for basic hygienic applications with easy-to-use operation concept
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for Basic Hygienic Applications with Easy-to-Use Operation
Designed for applications with sanitary requirements.
-
Sensor features
Flexible Installation with Numerous Hygienic Process Connections
Energy-Saving Flow Measurement with No Pressure Loss
Maintenance-Free Design with No Moving Parts
Liner Material: PFA
Sensor Housing: Stainless Steel (3-A, EHEDG)
Wetted Materials CIP-/SIP-Cleanable -
Transmitter features
Optimum Usability with Display Touch Screen or Mobile App
Simple, Time-Saving Commissioning with Guided Parameterization
Integrated Verification with Heartbeat Technology
System Integration: HART, Modbus RS485, IO-Link
Flexible Operation with App and Optional Display -
Nominal diameter range
DN 2 to 150 (???? to 6″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone) -
Measured variables
Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
conductivity -
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.06 dm?/min to 600 m?/h (0.015 to 2650 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
Standard: IP66/67, type 4X enclosure
-
Display/Operation
2.4″ LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
CSA, GP, KC
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (T?V S?D attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP
商品評價