Flowmeter for smallest flow rates with genuine loop-powered technology
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for Smallest Flow Rates with Genuine Loop-Powered Technology
Designed for Measurement of Smallest Flow Quantities -
Sensor features
Flexible Installation with Numerous Process Connections
Energy-Saving Flow Measurement with No Pressure Loss
Maintenance-Free Design with No Moving Parts
Liner Material: PFA
Sensor Housing: Stainless Steel
Various Electrode Materials Available -
Transmitter features
Convenient Device Wiring with Separate Connection Compartment
Safe Operation with Display, Touch Control, and Background Lighting
Integrated Verification with Heartbeat Technology
Loop-Powered Technology
Robust Dual-Compartment Housing
Worldwide Approvals (SIL, Hazardous Area) -
Nominal diameter range
DN 2 to 25 (???? to 1″)
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum -
Measured variables
Volume flow, mass flow
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
-
Measuring range
0.06 dm?/min to 300 m?/h (0.015 to 80 gal/min)
-
Max. process pressure
PN 40, Class 150, 20K
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
-
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex
-
Product safety
CE, C-Tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (T?V S?D attestation) -
Pressure approvals and certificates
CRN
-
Material certificates
3.1 material
商品評價