Refueling application flowmeter with easy system integration
-
Measuring principle
Coriolis
-
Product headline
A flowmeter designed for refueling applications, offering seamless system integration and accurate measurement of cryogenic gases.
-
Sensor features
Ensure excellent operational safety with reliable performance even under extreme ambient conditions. This flowmeter reduces the need for process measuring points by offering multivariable measurement capabilities, including flow, density, and temperature. Its space-saving design eliminates the requirement for inlet and outlet runs. Capable of measuring flow rates up to 18,000 kg/h (660 lb/min), it can handle medium temperatures as low as -196 °C (-321 °F), making it suitable for a wide range of demanding industrial applications.
-
Transmitter features
Compact and space-saving transmitter design that offers full functionality within a minimal footprint. Enjoy fast commissioning with pre-configured devices and automatic data recovery for servicing convenience. The transmitter features a robust and compact housing, ensuring durability in various industrial environments. It supports Modbus RS485 communication protocol for seamless integration into control systems.
-
Nominal diameter range
DN 8 to 25 (? to 1″)
-
Wetted materials
Measuring tubes: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow
-
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
(Reference condition) -
Measuring range
0 to 18 000 kg/h (0 to 660 lb/min)
-
Max. process pressure
PN 40, Class 300
-
Medium temperature range
–196 to +125 °C (–320 to +257 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
No local operation
Configuration via operating tools possible -
Outputs
None
-
Inputs
None
-
Digital communication
Modbus RS485
-
Power supply
DC 20 to 30 V
-
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, EAC
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
CRN -
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
-
Material certificates
3.1 material