A dual-compartment transmitter housing provides isolation from the external environment. Advanced diagnostics and through-the-glass Local Operator Interface offer unparalleled process insight.

Specifications
Sensor compatibility
Compatible with Rosemount 8705, 8711 and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers.
Transmitter coil drive current
500mA
Flow rate range
Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits
Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply
90 – 250VAC, 50/60Hz or 12 – 42VDC
Switch-on current
AC: Maximum 35.7A (< 5ms) at 250VAC
DC: Maximum 42A (< 5ms) at 42VDC