JUHE FUTURE INTERNATIONAL LIMITED
specializes in distributing test and measurement instruments. We have a professional global service team to provide high-quality and efficient services.
About Us
Electromagnetic FlowMeters
Specs at a glance Max. measurement error Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.) Measuring range 0.5 to 3750 kg/h (1.1 to 8250 lb/h) Medium temper……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 % Measuring range ……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 % Measuring range ……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature c……
Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature c……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature c……
Specs at a glance Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature c……
Specs at a glance Max. measurement error Volume flow: +/-0.8% o.r. +/- 0.1% o.f.s Measuring range up to 750 l/min Medium temperature range -10 to 70°C (+14 to +158 °F) Pe……
specializes in distributing test and measurement instruments. We have a professional global service team to provide high-quality and efficient services.